When installing LED explosion-proof lights, it is very important to standardize the wiring

Generally speaking, the applicable environment of LED explosion-proof lights is quite special, and all the wiring of LED explosion-proof lights should be more careful when installing them, including the choice of orientation, the choice of wire materials, etc...


1. Orientation selection


The circuit should be placed in a place where the risk of explosion is relatively small or away from ignition sources.


2. Isolation and sealing


Circuits and protection pipes, cables or steel pipe layers should be tightly blocked with non-combustible materials when passing through the partition walls or slabs between different levels of explosion hazard areas.


3. Selection of laying method


Explosion-hazardous environment circuits are mainly explosion-proof steel pipe wiring and cable wiring.


4. Selection of wire material


Copper wire or cable should be used in the area within the distribution line of explosion hazard environment hazard class 1. In the case of severe vibration, stranded copper core cable or stranded copper wire should be used. Aluminum core power cables shall not be used in underground coal mines.


Explosion hazard environment hazard level 2 is within this range, the power line should be made of aluminum wire or cable with a cross-sectional area of 4mm2 or more, and the cross-sectional area of the lighting circuit should be 2.5mm2. and above the aluminum core wire or cable.


5. Allowable carrying capacity


In the selection of the section of the insulated wire and the section of the cable in Zone 1 and Zone 2, the allowable carrying capacity of the conductor should not be less than 1.25 times the rated current of the fuse and the long-time overcurrent release of the circuit breaker. The allowable current carrying capacity of the branch line of the low-voltage cage asynchronous motor should not be less than 1.25 times the rated current of the motor.


6. Connection of electrical circuits


It is necessary that the central connection of the circuit in Zone 1 and Zone 2 is near an explosion-proof junction box or junction box that is compatible with the hazardous environment. Zone 1 should choose a fire junction box, and Zone 2 can be used to add a type of junction box.


If you choose an aluminum core cable or wire for the 2-zone circuit, it must be reliable to facilitate the equipment and protection of the user.


Things to keep in mind


1. Eliminate the dust and dirt on the explosion-proof lamp on time, and improve the luminous power and heat dissipation function of the bulb. The cleaning method can be based on the protection ability of the lamp housing, using water (the shadow symbol on the lamp) or wiping with a damp cloth. When spraying water, the power supply should be cut off, and it is strictly forbidden to clean the plastic case (transparent) with a dry cloth to avoid static electricity.


2. Check whether the traces of the transparent part are affected by foreign matter, whether the protective net is loose, desoldered, corroded, etc. If this is the case, it should be discontinued and repaired and replaced in time.


3. The humid environment is used in the bulb cavity. If you want to eradicate the moisture in time, please replace the seal to ensure the protective function of the shell.


4. If the light source is damaged, the lamp should be stopped in time and replaced, so as to prevent the light source from being unable to begin to cause the electrical components such as the ballast to be in an abnormal state for a long time.


5. When opening the lampshade, press the warning board to request, turn off the power and open the cover.


6. After opening the cover, it should be inspected by the method of the fireproof joint surface intact, the rubber seal is hardened or sticky, the wire insulation is green and carbonaceous, and the insulation and electrical parts are deformed and burnt marks. If these problems are found, they should be replaced in time.


7. Part of the bulb cannot be disassembled and is often opened. Sealing technology; more in line with my country's new explosion-proof technology.


8. In the case of modifying the wet cloth (not too wet), apply the cover, the luminous, lighting and transparent parts, and then increase the luminous power of the lamp. A thin layer of 204-1 should be applied to the fireproof surface instead of anti-rust oil, and the seals should be covered with attention to whether the seals play a sealing role in the original position.

Benwei Lighting is an LED Tube, LED flood light, LED Panel Light, LED High Bay, LED  manufacturer with 12 years of experience. If you want to purchase a high-quality LED flood light or have a more in-depth understanding of the application of LED flood lights, please contact send us inquiry, our web: https://www.benweilight.com/.