Knowledge

Home/Knowledge/Details

FIFA standard TV or no TV for LED stadium lighting

FIFA standard TV or no TV for LED stadium lighting

Televised Events

Class V ........ International

Class IV........ National

Non-televised competitions

Class III ...... National games

Class II ........ Leagues and clubs

Class I ..........Training and Recreation

Lighting specifications for NON TELEVISED events

Lighting specifications for NON TELEVISED events

Activity level Class.

Horizontal
illuminance

Uniformity

Glare rating

Lamp colour
temperature

Lamp colour
rendering

Eh ave(lux)

U2

GR

Tk

Ra

National games
Class Ⅲ

500*

0.7

≤50

Tk>4000 K

≥80

Leagues &clubs Class Ⅱ

200*

0.6

≤50

Tk>4000 K

≥65

Training&recreation
Class Ⅰ

75*

0.5

≤50

Tk>2000 K

≥20

Lighting specifications for TELEVISED events

Lighting specifications for TELEVISED events

Class

Calculation
toward

VERTICAL
ILLUMINANCE*

HORIZONTAL
ILLUMINANCE

PROPERTIES
OF LAMPS

Ey cam
Ave.

Uniformity

Eh.Ave.

Uniformity

Colour
temperature

Colour
rendering

LUx

U1

U2

LUX

U1

U2

Tk

Ra

International
Class V

Slow motion cameras

1800

0.5

0.7

1500 to 3000

0.6

0.8

Tk>5500 K

≥80
pref.90

Fixed camera

1400

0.5

0.7

Mobile cameras
(at pitch level)

1000

0.3

0.5

National Class IV &continuity
of broadcastinc

Fixed
camera

1000

0.4

0.6

1000 to 2000

0.6

0.8

Tk>4000 K

≥80