FIFA standard TV or no TV for LED stadium lighting
Televised Events
Class V ........ International
Class IV........ National
Non-televised competitions
Class III ...... National games
Class II ........ Leagues and clubs
Class I ..........Training and Recreation
Lighting specifications for NON TELEVISED events
|
Lighting specifications for NON TELEVISED events |
|||||
|
Activity level Class. |
Horizontal |
Uniformity |
Glare rating |
Lamp colour |
Lamp colour |
|
Eh ave(lux) |
U2 |
GR |
Tk |
Ra |
|
|
National games |
500* |
0.7 |
≤50 |
Tk>4000 K |
≥80 |
|
Leagues &clubs Class Ⅱ |
200* |
0.6 |
≤50 |
Tk>4000 K |
≥65 |
|
Training&recreation |
75* |
0.5 |
≤50 |
Tk>2000 K |
≥20 |
Lighting specifications for TELEVISED events
|
Lighting specifications for TELEVISED events |
|||||||||
|
Class |
Calculation |
VERTICAL |
HORIZONTAL |
PROPERTIES |
|||||
|
Ey cam |
Uniformity |
Eh.Ave. |
Uniformity |
Colour |
Colour |
||||
|
LUx |
U1 |
U2 |
LUX |
U1 |
U2 |
Tk |
Ra |
||
|
International |
Slow motion cameras |
1800 |
0.5 |
0.7 |
1500 to 3000 |
0.6 |
0.8 |
Tk>5500 K |
≥80 |
|
Fixed camera |
1400 |
0.5 |
0.7 |
||||||
|
Mobile cameras |
1000 |
0.3 |
0.5 |
||||||
|
National Class IV &continuity |
Fixed |
1000 |
0.4 |
0.6 |
1000 to 2000 |
0.6 |
0.8 |
Tk>4000 K |
≥80 |
LED Sports Stadium lighting is designed according to level requirements when When meeting FIFA standards. After the system installation is completed and before important games, lighting inspections should be conducted
Sunny 2024-5-29