Field Area Differences Between Softball and Baseball
We must first comprehend the dimensions of the two locations in order to comprehend the illumination configuration for the baseball and softball fields. The majority of baseball and softball fields are outdoors.
Inside and outside fields make up the softball pitch. The square field is another name for the interior field. The street perimeter on two sides in the inner boundary region and the other two sides on the outside boundary area make up the inside field. The center area measures 27.5 x 27.5 meters. The exterior area is shaped like a fan. Second base is at least 121.92 meters from home plate to the outer field, and the unanticipated area of the outer field is 18.29 meters.
A type of multidirectional air action is softball. Inside field and outside field are additional divisions. The outside area is curved like a fan and measures 27.5 x 27.5 meters. The region inside the barrier is 7.62 meters outside the field and on both sides, and the outside field has a radius of R=61-70 meters.
Baseball Field Lighting Lay Out
1. Either the led sport light can be placed on the street above the theater, or the lighting plan for the baseball field can use six or eight lamp posts.
2. The baseball pole is situated 20 degrees outside of the four baseball blocks' primary view point. In the dark area of Figure 2 below, the rod should not be positioned.
Softball Field Lighting Layout 1. The baseball field light can be placed on the street above the theater, or the softball field lamp should use at least four lamp posts.
2. The softball field light post should be placed in a zone that is 20 degrees or more from the primary view angle of the four basement regions. The dark area of Figure 1 below should not be where the lamppost is placed.
Field lighting for baseball and softball requires care to detail
1. Light needs to come from three or four areas in order to provide athletes with a decent lighting environment and minimize shadows. All stadium lighting requirements must be met, including mounting height, glare control, stadium lamp group, and light beam extension. location of the stadium light. The location of the LED stadium lighting should mirror the path of the game. Image 1 depicts where "A, B, and C" are located.
2. Control of glare. Position the arena light away from the players' devoted line of sight. The triangular region stretching from each infield boundary in Figure 1 creates a 20 degree zone.
3. The field light beam's expansion. The specified beam's top should be at least 10 degrees below the stadium's lamp line.
4. The light pole's installation height. All lighting posts must have the sport ground light installed at least 21.3 meters above the ground. The mounting height of the led stadium light above must be increased in order to increase the number of lamp poles. According to the following method, the height criteria for lamp poles in Areas A, B, and C of Figure 3 can be computed differently.
Pitchers and infielders are illuminated by Zone A lights. Height of "A" pole: 90' plus (SETBACK / 2).
The infield and fields are illuminated by Zone B posts. d / 3 "B" pole height (d is the distance from the pole to the symmetrical separation line of the site).
The light tower in Zone C illuminates the outfield and is situated outside the field's barrier. "C" pole height equals the luminaire's furthest projection distance divided by two.

Benwei stadium flood light
【Power】500W 1000W 1500W
【Input Voltage】AC85-265V,400V
【Lighting Effect】150lm/W
【CRI】Ra≥70
【IP Rate】IP66
【Beam Angle】30°/60°/90°optional
【CCT】2700-6500K
【PF】PF≥0.95
【Surge Protection】≥4KV