Knowledge

Home/Knowledge/Details

Talking about the installation requirements of high pole lights

Talking about the installation requirements of high pole lights


1. The main rod adopts one-time forming, the welding seam of the steel rod (Q235) must be flat and smooth, and the flatness error of the welding seam of the whole rod body and the rod body should not be greater than ±1mm. The welding method of the lamp pole is automatic argon arc welding, and the color flaw detection inspection meets the requirements of the welding international GB/T3323-1989111 standard. The lamp pole socketing method is fixed by nails and top wires.

 


2. The anti-corrosion treatment of the light pole is hot-dip galvanizing, the surface of the galvanized layer is smooth and beautiful, and the gloss is consistent. No wrinkles, dropouts, zinc tumors, peeling, half-spots, yin and yang defects, the thickness of the zinc layer is more than 85μm, the adhesion of the galvanized layer should meet the GB2694-98 standard, guarantee 8 years of no fading, and wind resistance of the light pole The capacity is designed at 36.9 m/s. The anti-corrosion life of the pole is more than 20 years.

 


3. The surface of the light pole is sprayed with a thickness of ≥100μm, the adhesion reaches GB9286-880, and the surface is smooth: the hardness is ≥2H, the outdoor weather-resistant material is used, and the sprayed material is all polyester powder.